Brief

Here is a summary of the provided document:

Summary:

The Cybersecurity and Infrastructure Security Agency (CISA) has announced that it will no longer update ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. The advisory warns of three vulnerabilities in Siemens' JT2Go and Teamcenter Visualization software, including an out-of-bounds read, a NULL pointer dereference, and two stack-based buffer overflows. These vulnerabilities could allow an attacker to execute code in the context of the software's current process or crash the application, potentially causing a denial of service. The CVEs assigned to these vulnerabilities are CVE-2023-51439, CVE-2023-51744, and CVE-2023-51745. The advisory recommends updating software to the latest version and provides additional mitigations, such as minimizing network exposure and using secure remote access methods.

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3: 7.8
  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: JT2Go, Teamcenter Visualization
  • Vulnerabilities: Out-of-bounds Read, NULL Pointer Dereference, Stack-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the software’s current process or crash the application causing a denial of service.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • JT2Go: All versions prior to V14.3.0.6
  • Teamcenter Visualization V13.3: All versions prior to V13.3.0.13
  • Teamcenter Visualization V14.1: All versions prior to V14.1.0.12
  • Teamcenter Visualization V14.2: All versions prior to V14.2.0.9
  • Teamcenter Visualization V14.3: All versions prior to V14.3.0.6

3.2 Vulnerability Overview

3.2.1 OUT-OF-BOUNDS READ CWE-125

The affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.

CVE-2023-51439 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.2 NULL POINTER DEREFERENCE CWE-476

The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.

CVE-2023-51744 has been assigned to this vulnerability. A CVSS v3.1 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L).

3.2.3 STACK-BASED BUFFER OVERFLOW CWE-121

The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.

CVE-2023-51745 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C).

3.2.4 STACK-BASED BUFFER OVERFLOW CWE-121

The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.

CVE-2023-51746 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens recommends users update software to mitigate risk from these vulnerabilities.

  • JT2Go: Update to V14.3.0.6 or later version
  • Teamcenter Visualization V13.3: Update to V13.3.0.13 or later version
  • Teamcenter Visualization V14.1: Update to V14.1.0.12 or later version
  • Teamcenter Visualization V14.2: Update to V14.2.0.9 or later version
  • Teamcenter Visualization V14.3: Update to V14.3.0.6 or later version

Siemens also recommends that users avoid opening untrusted CGM files in JT2Go and Teamcenter Visualization.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.

5. UPDATE HISTORY

  • January 11, 2024: Initial Publication Date

Highlights content goes here...

Summary:

Document Title: CISA-2023-001: Out-of-Bounds Read, NULL Pointer Dereference, and Stack-Based Buffer Overflow Vulnerabilities in Siemens JT2Go and Teamcenter Visualization

Summary:

The Cybersecurity and Infrastructure Security Agency (CISA) has announced vulnerabilities in Siemens JT2Go and Teamcenter Visualization software. These vulnerabilities, which include out-of-bounds read, NULL pointer dereference, and stack-based buffer overflow flaws, could allow attackers to execute code, crash the application, or cause denial-of-service (DoS) conditions. The affected products are JT2Go and Teamcenter Visualization versions prior to V14.3.0.6, V13.3.0.13, V14.1.0.12, V14.2.0.9, and V14.3.0.6.

Risks:

The exploitation of these vulnerabilities could result in the execution of code in the context of the software’s current process, application crashes, or DoS conditions. An attacker could leverage these vulnerabilities to gain unauthorized access, steal sensitive information, or disrupt critical infrastructure.

MITIGATIONS:

The vendor, Siemens, recommends updating software to the latest versions:

JT2Go: Update to V14.3.0.6 or later
Teamcenter Visualization V13.3: Update to V13.3.0.13 or later
Teamcenter Visualization V14.1: Update to V14.1.0.12 or later
Teamcenter Visualization V14.2: Update to V14.2.0.9 or later
Teamcenter Visualization V14.3: Update to V14.3.0.6 or later

Additionally, Siemens recommends avoiding opening untrusted CGM files in JT2Go and Teamcenter Visualization.

DEFENSIVE MEASURES:

CISA recommends taking the following defensive measures:

Minimize network exposure for all control system devices and/or systems
Locate control system networks and remote devices behind firewalls and isolating them from business networks
Use more secure methods, such as Virtual Private Networks (VPNs)
Perform proper impact analysis and risk assessment prior to deploying defensive measures

UPDATE HISTORY:

The document was initially published on January 11, 2024.

Conclusion:*

The vulnerabilities in Siemens JT2Go and Teamcenter Visualization software pose a significant risk to critical infrastructure. Organizations using these products are advised to update software to the latest versions and take defensive measures to minimize the risk of exploitation.

Cybersecurity and Infrastructure Security Agency

Quick Insight
RADA.AI
RADA.AI
Hello! I'm RADA.AI - Regulatory Analysis and Decision Assistance. Your Intelligent guide for compliance and decision-making. How can i assist you today?
Suggested

Form successfully submitted. One of our GRI rep will contact you shortly

Thanking You!

Enter your Email

Enter your registered username/email id.

Enter your Email

Enter your email id below to signup.

Enter your Email

Enter your email id below to signup.
Individual Plan
$125 / month OR $1250 / year
Features
Best for: Researchers, Legal professionals, Academics
Enterprise Plan
Contact for Pricing
Features
Best for: Law Firms, Corporations, Government Bodies