Brief

Here is a summary of the provided document:

Summary:

The document discusses a vulnerability in Crestron's AirMedia Presentation System product, AM-300, specifically firmware version 1.4499.00018. The vulnerability, identified as OS Command Injection (CVE-2023-6926), allows a limited-access SSH session user to escalate their privileges to root-level access. The CVSS v3.1 base score is 8.4. To mitigate this vulnerability, Crestron has released firmware version 1.4499.00023.001 or higher, and CISA recommends minimizing network exposure, utilizing firewalls, and using secure remote access methods such as VPNs.

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 8.4
  • ATTENTION: Low attack complexity
  • Vendor: Crestron
  • Equipment: AM-300
  • Vulnerability: OS Command Injection

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to escalate their privileges to root-level access.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Crestron AirMedia Presentation System products are affected:

  • AM-300: Version 1.4499.00018

3.2 Vulnerability Overview

3.2.1 CWE-78: Improper Neutralization of Special Elements used in an OS Command (‘OS Command Injection’)

There is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.

CVE-2023-6926 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.4 has been calculated; the CVSS vector string is AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Uri Katz of Claroty Research Team82 reported this vulnerability to CISA.

4. MITIGATIONS

Crestron has resolved this vulnerability in firmware version 1.4499.00023.001 or higher. Please see https://security.crestron.com or contact True Blue Support for additional information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

  • January 23, 2024: Initial Publication

Highlights content goes here...

Summary:

View CSAF: Crestron AM-300 OS Command Injection Vulnerability

The View CSAF document provides a detailed analysis of a critical vulnerability affecting the Crestron AM-300 AirMedia Presentation System. The vulnerability, classified as OS Command Injection (CWE-78), allows attackers to escalate privileges to root-level access. The vulnerability affects firmware version 1.4499.00018, and CVSS v3.1 base score is 8.4.

Risk Evaluation:

The successful exploitation of this vulnerability could enable an attacker to obtain root-level access, posing a significant risk to the affected systems and organizations. The vulnerability is not exploitable remotely, but attackers may attempt to access the system through other means.

Technical Details:

The vulnerability is present in the Crestron AM-300 firmware version 1.4499.00018 and affects the following products:

AM-300: Version 1.4499.00018

The vulnerability is attributed to Uri Katz of Claroty Research Team82, and CVSS v3.1 base score is 8.4.

Mitigations:

Crestron has released a patched firmware version, 1.4499.00023.001 or higher, which addresses the vulnerability. Users are advised to update to the latest firmware version. Additionally, CISA recommends minimizing network exposure, locating control systems behind firewalls, and using more secure remote access methods, such as Virtual Private Networks (VPNs).

Update History:

The document was initially published on January 23, 2024.

Recommendations:

Organizations are advised to:

1. Minimize network exposure for control system devices and software.
2. Locate control systems behind firewalls and isolate them from business networks.
3. Use more secure remote access methods, such as Virtual Private Networks (VPNs).
4. Update to the latest firmware version (1.4499.00023.001 or higher).
5. Implement control systems security recommended practices.

Sources:

Crestron View CSAF document
CISA CVE-2023-6926 page
CISA ICS webpage

By following these recommendations and keeping the system up-to-date with the latest firmware version, organizations can reduce the risk of exploitation and protect their critical infrastructure.

Cybersecurity and Infrastructure Security Agency

Quick Insight
RADA.AI
RADA.AI
Hello! I'm RADA.AI - Regulatory Analysis and Decision Assistance. Your Intelligent guide for compliance and decision-making. How can i assist you today?
Suggested

Form successfully submitted. One of our GRI rep will contact you shortly

Thanking You!

Enter your Email

Enter your registered username/email id.

Enter your Email

Enter your email id below to signup.

Enter your Email

Enter your email id below to signup.
Individual Plan
$125 / month OR $1250 / year
Features
Best for: Researchers, Legal professionals, Academics
Enterprise Plan
Contact for Pricing
Features
Best for: Law Firms, Corporations, Government Bodies